<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>มาตรฐานและกฎระเบียบ &#8211; Clean Room Validation &amp; Certification Standard NEBB ISO</title>
	<atom:link href="https://qv-test.com/category/standards-regulations/feed/" rel="self" type="application/rss+xml" />
	<link>https://qv-test.com</link>
	<description>Clean Room Validation &#38; Certification Standard NEBB ISO</description>
	<lastBuildDate>Fri, 30 Oct 2026 01:49:40 +0000</lastBuildDate>
	<language>th</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://qv-test.com/wp-content/uploads/2025/09/Asset-3-150x150.png</url>
	<title>มาตรฐานและกฎระเบียบ &#8211; Clean Room Validation &amp; Certification Standard NEBB ISO</title>
	<link>https://qv-test.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ประกาศ สธ. GMP พ.ศ. 2569: ใช้ PIC/S PE 009-17 และ Annex 1 ฉบับใหม่เริ่มเมื่อไร</title>
		<link>https://qv-test.com/moph-gmp-2569-pics-pe-009-17-annex-1/</link>
		
		<dc:creator><![CDATA[qvadmin adminadmin]]></dc:creator>
		<pubDate>Tue, 27 Oct 2026 02:38:08 +0000</pubDate>
				<category><![CDATA[มาตรฐานและกฎระเบียบ]]></category>
		<guid isPermaLink="false">https://qv-test.com/moph-gmp-2569-pics-pe-009-17-annex-1/</guid>

					<description><![CDATA[ประกาศ สธ. พ.ศ. 2569 ให้ใช้ PIC/S PE 009-17 โดย Annex 1 ยังใช้ตาม PE 009-16 ได้ถึง 31 ธ.ค. 2572 สรุปค่าอนุภาค รอบรับรองซ้ำ และการทดสอบห้องสะอาดที่เปลี่ยน]]></description>
										<content:encoded><![CDATA[
<div class="qv-art">
<p class="qv-art-cat">มาตรฐานและกฎระเบียบ</p>
<h1 class="qv-art-h1">ประกาศ สธ. GMP พ.ศ. 2569: ใช้ PIC/S PE 009-17 และ Annex 1 ฉบับใหม่เริ่มเมื่อไร</h1>
<p class="qv-art-meta">เขียนโดย <strong>ทีมวิศวกร QV TEST</strong> · เผยแพร่ 27 ต.ค. 2569 · อัปเดต 27 ต.ค. 2569 · อ่าน 5 นาที</p>
<div class="qv-art-short"><strong>คำตอบสั้น:</strong> ประกาศกระทรวงสาธารณสุข เรื่อง กำหนดหลักเกณฑ์และวิธีการในการผลิตยา ตามกฎหมายว่าด้วยยา พ.ศ. 2569 ให้ผู้ผลิตยาแผนปัจจุบันปฏิบัติตาม PIC/S GMP Guide ฉบับ PE 009-17 ยกเว้น Annex 1 (การผลิตยาปราศจากเชื้อ) ที่ให้ใช้ตาม PE 009-16 ได้จนถึงวันที่ 31 ธันวาคม พ.ศ. 2572 สำหรับห้องสะอาด ค่าอนุภาค ≥ 0.5 µm ของ Grade A–D เท่าเดิม แต่ค่า ≥ 5 µm รอบการรับรองซ้ำ และรายการทดสอบใน Annex 1 ฉบับ PE 009-17 เขียนไว้ชัดขึ้น</div>
<figure class="qv-art-cover"><img fetchpriority="high" width="1024" height="765" src="https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-1024x765.webp" class="skip-lazy no-lazy" alt="ชั้นเอกสารรายงานการทดสอบสำหรับเตรียมรับการตรวจ GMP PIC/S" data-no-lazy="1" loading="eager" fetchpriority="high" sizes="(min-width:820px) 760px, 100vw" decoding="async" srcset="https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-1024x765.webp 1024w, https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-300x224.webp 300w, https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-768x574.webp 768w, https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness.webp 1400w" /></figure>
<nav class="qv-art-toc"><p>ในบทความนี้</p><ol><li><a href="#notice">ประกาศฉบับนี้กำหนดอะไร</a></li><li><a href="#timeline">Annex 1 ฉบับไหนใช้เมื่อไร</a></li><li><a href="#particles">ค่าอนุภาคเปลี่ยนอะไรบ้าง</a></li><li><a href="#tests">การรับรองห้องสะอาดตาม PE 009-17</a></li><li><a href="#prepare">ควรเตรียมอะไรตั้งแต่ตอนนี้</a></li><li><a href="#faq">คำถามที่พบบ่อย</a></li></ol></nav>
<h2 id="notice">ประกาศฉบับนี้กำหนดอะไร</h2>
<table><thead><tr><th>หัวข้อ</th><th>สาระสำคัญ</th><th>ข้อในประกาศ</th></tr></thead><tbody>
<tr><td>วันที่</td><td>ประกาศ ณ วันที่ 1 กรกฎาคม 2569 ลงราชกิจจานุเบกษา 3 กรกฎาคม 2569 (เล่ม 143 ตอนพิเศษ 164 ง) มีผลเมื่อพ้นกำหนด 30 วันนับแต่วันประกาศในราชกิจจานุเบกษา</td><td>ข้อ 1</td></tr>
<tr><td>ประกาศที่ยกเลิก</td><td>ประกาศเรื่องหลักเกณฑ์การผลิตยาแผนโบราณ พ.ศ. 2559 และประกาศเรื่องหลักเกณฑ์การผลิตยาแผนปัจจุบัน พ.ศ. 2567</td><td>ข้อ 2</td></tr>
<tr><td>มาตรฐานที่ใช้</td><td>PIC/S Guide to Good Manufacturing Practice for Medicinal Products Part I, Part II และ Annexes ฉบับ PE 009-17 (ภาคผนวก 1 ของประกาศ)</td><td>ข้อ 3</td></tr>
<tr><td>ข้อยกเว้น</td><td>Annex 1 ให้ใช้ตาม PE 009-16 จนถึง 31 ธันวาคม 2572 และไม่รวม Annex 6 (Manufacture of medicinal gases)</td><td>ข้อ 3 (1)–(2)</td></tr>
<tr><td>ผู้ผลิตวัคซีนออโตจีนัสสำหรับสัตว์</td><td>ใช้ Adapted GMP principles for inactivated veterinary autogenous vaccines ของสหภาพยุโรป (ภาคผนวก 2)</td><td>ข้อ 4</td></tr>
</tbody></table>
<h2 id="timeline">Annex 1 ฉบับไหนใช้เมื่อไร</h2>
<table><thead><tr><th>ช่วงเวลา</th><th>Annex 1 ที่ใช้ตามประกาศ</th></tr></thead><tbody>
<tr><td>ตั้งแต่ประกาศมีผล ถึง 31 ธ.ค. 2572</td><td>Annex 1 ตาม PIC/S PE 009-16</td></tr>
<tr><td>หลัง 31 ธ.ค. 2572</td><td>Annex 1 ตาม PIC/S PE 009-17 (ฉบับลงวันที่ 25 สิงหาคม 2023 ที่แนบท้ายประกาศ)</td></tr>
</tbody></table>
<p>ส่วนอื่นของ GMP (Part I, Part II และ Annex อื่น ยกเว้น Annex 6) ใช้ฉบับ PE 009-17 ตั้งแต่ประกาศมีผล ดังนั้นโรงงานยาปราศจากเชื้อมีช่วงเปลี่ยนผ่านสำหรับ Annex 1 แต่ควรวางแผนให้ห้องสะอาด เอกสารการรับรอง และโปรแกรมเฝ้าระวังพร้อมก่อนสิ้นปี 2572</p>
<h2 id="particles">ค่าอนุภาคเปลี่ยนอะไรบ้าง</h2>
<p>ตารางเปรียบเทียบขีดจำกัดอนุภาคสำหรับการจัดระดับห้องสะอาด (อนุภาคต่อ m³)</p>
<table><thead><tr><th>Grade</th><th>≥ 0.5 µm at rest / in operation (ทั้งสองฉบับ)</th><th>≥ 5 µm ตาม PE 009-16</th><th>≥ 5 µm ตาม PE 009-17 (Table 1)</th></tr></thead><tbody>
<tr><td>A</td><td>3,520 / 3,520</td><td>20 / 20</td><td>ไม่กำหนด (a) / ไม่กำหนด (a)</td></tr>
<tr><td>B</td><td>3,520 / 352,000</td><td>29 / 2,900</td><td>ไม่กำหนด (a) / 2,930</td></tr>
<tr><td>C</td><td>352,000 / 3,520,000</td><td>2,900 / 29,000</td><td>2,930 / 29,300</td></tr>
<tr><td>D</td><td>3,520,000 / ไม่กำหนด</td><td>29,000 / ไม่กำหนด</td><td>29,300 / ไม่กำหนดล่วงหน้า (b)</td></tr>
</tbody></table>
<p class="qv-art-note">(a) PE 009-17 ระบุว่าอาจพิจารณาจัดระดับรวมอนุภาค 5 µm หาก CCS หรือแนวโน้มข้อมูลในอดีตบ่งชี้ (b) Grade D ขณะทำงาน ผู้ผลิตกำหนดขีดจำกัดเองจากการประเมินความเสี่ยงและข้อมูลประจำ ส่วนการเฝ้าระวัง (monitoring) ตาม Table 5 ของ PE 009-17 กำหนดค่า ≥ 5 µm ของ Grade A ที่ 29 และ Grade B at rest ที่ 29</p>
<p>ใน PE 009-16 ข้อ 5 ระบุว่า Grade A เทียบเท่า ISO 4.8 เพราะค่า ≥ 5.0 µm ที่ 20 อนุภาคต่อ m³ ส่วนใน PE 009-17 การจัดระดับ Grade A ใช้ค่า ≥ 0.5 µm ที่ 3,520 เป็นหลัก</p>
<h2 id="tests">การรับรองห้องสะอาดตาม PE 009-17</h2>
<p>Annex 1 ฉบับ PE 009-17 ข้อ 4.25 กำหนดรายการทดสอบในการรับรองห้องสะอาดและอุปกรณ์อากาศสะอาด (เท่าที่เกี่ยวข้องกับการออกแบบหรือการใช้งาน) ได้แก่ การทดสอบรอยรั่วและความสมบูรณ์ของระบบกรองที่ติดตั้ง ปริมาณและความเร็วลม ความแตกต่างของแรงดัน ทิศทางและการแสดงภาพการไหลของอากาศ การปนเปื้อนจุลินทรีย์ในอากาศและพื้นผิว อุณหภูมิ ความชื้นสัมพัทธ์ การคืนสภาพ (recovery) และการรั่วของระบบกักกัน</p>
<table><thead><tr><th>หัวข้อ</th><th>สิ่งที่ PE 009-17 Annex 1 กำหนด</th><th>ข้อ</th></tr></thead><tbody>
<tr><td>สถานะที่จัดระดับ</td><td>ทั้ง at rest และ in operation ค่า at rest ต้องได้หลังช่วง clean up (ค่าแนะนำน้อยกว่า 20 นาที)</td><td>4.29</td></tr>
<tr><td>ความเร็วลมแบบทิศทางเดียว</td><td>ค่าแนะนำ 0.36–0.54 m/s ที่ตำแหน่งทำงาน เว้นแต่มีเหตุผลทางวิทยาศาสตร์ใน CCS</td><td>4.30</td></tr>
<tr><td>จุลินทรีย์ขณะรับรอง (Table 2)</td><td>Grade A ไม่พบการเจริญ · B: อากาศ 10 CFU/m³ จานตั้ง 5 CFU/4 ชม. จานสัมผัส 5 CFU · C: 100 / 50 / 25 · D: 200 / 100 / 50</td><td>4.31</td></tr>
<tr><td>การรับรองซ้ำขั้นต่ำ</td><td>จัดระดับอนุภาค, ความสมบูรณ์ของแผ่นกรองขั้นสุดท้าย, ปริมาณลม, ความแตกต่างของแรงดัน และความเร็วลม (Grade B, C, D ตามการประเมินความเสี่ยงใน CCS ส่วนพื้นที่ไม่ใช่ทิศทางเดียวใช้การทดสอบการคืนสภาพแทน)</td><td>4.32</td></tr>
<tr><td>รอบการรับรองซ้ำสูงสุด</td><td>Grade A และ B ไม่เกิน 6 เดือน · Grade C และ D ไม่เกิน 12 เดือน และต้องทำซ้ำหลังแก้ไขหรือเปลี่ยนแปลงที่มีนัยสำคัญ</td><td>4.32</td></tr>
<tr><td>จำนวนจุดเก็บตัวอย่าง</td><td>ขั้นต่ำตาม ISO 14644-1 และพิจารณาจุดเพิ่มในพื้นที่ Grade A และ B เช่น จุดบรรจุ</td><td>4.28</td></tr>
</tbody></table>
<h2 id="prepare">ควรเตรียมอะไรตั้งแต่ตอนนี้</h2>
<ul>
<li>ทบทวนรายงานจัดระดับห้องสะอาดเดิมว่ามีผลอนุภาค ≥ 5 µm และผลจุลินทรีย์ทั้ง at rest และ in operation ครบหรือไม่</li>
<li>ตรวจว่ารอบการรับรองซ้ำของพื้นที่ Grade A และ B ไม่เกิน 6 เดือน และ Grade C และ D ไม่เกิน 12 เดือน</li>
<li>กำหนดและบันทึกช่วง clean up ของแต่ละห้องระหว่างการรับรอง</li>
<li>ทบทวนเหตุผลของค่าความเร็วลมในโซนทิศทางเดียว และการทดสอบการคืนสภาพในพื้นที่ที่ไม่ใช่ทิศทางเดียว</li>
<li>เชื่อมผลการทดสอบเข้ากับกลยุทธ์ควบคุมการปนเปื้อน (CCS) ตามข้อ 2.3</li>
</ul>
<h2 id="faq">คำถามที่พบบ่อย</h2><div class="qv-art-faq"><details><summary>ตอนนี้ต้องใช้ Annex 1 ฉบับไหน?</summary><p>ตามประกาศ สธ. พ.ศ. 2569 ข้อ 3 (1) ใช้ Annex 1 ตาม PE 009-16 ได้จนถึง 31 ธันวาคม 2572 หลังจากนั้นใช้ตาม PE 009-17</p></details><details><summary>ค่าอนุภาค ≥ 0.5 µm ของ Grade A–D เปลี่ยนไหม?</summary><p>ไม่เปลี่ยน ทั้ง PE 009-16 และ PE 009-17 ใช้ 3,520 / 352,000 / 3,520,000 อนุภาคต่อ m³ ตาม Grade และสถานะเดิม ที่เปลี่ยนคือค่า ≥ 5 µm</p></details><details><summary>ต้องรับรองห้องสะอาดซ้ำบ่อยแค่ไหน?</summary><p>PE 009-17 Annex 1 ข้อ 4.32 กำหนดรอบสูงสุด Grade A และ B ทุก 6 เดือน และ Grade C และ D ทุก 12 เดือน</p></details></div>
<h2 id="refs">เอกสารอ้างอิง</h2><ul class="qv-art-refs"><li>ประกาศกระทรวงสาธารณสุข เรื่อง กำหนดหลักเกณฑ์และวิธีการในการผลิตยา ตามกฎหมายว่าด้วยยา พ.ศ. 2569 (ราชกิจจานุเบกษา เล่ม 143 ตอนพิเศษ 164 ง, 3 กรกฎาคม 2569) ข้อ 1–4</li><li>PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-17 (25 สิงหาคม 2023), Annex 1: Manufacture of sterile medicinal products ข้อ 2.3, 4.25–4.32, Table 1, 2 และ 5</li><li>PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-16 (1 กุมภาพันธ์ 2022), Annex 1 ข้อ 4–5</li></ul>
<div class="qv-art-author"><div class="qv-art-av">QV</div><div><strong>ทีมวิศวกร QV TEST</strong><span>ทีมทดสอบและตรวจรับรองห้องสะอาด ระบบ HVAC และระบบสนับสนุนการผลิต ของบริษัท คิววี เทสต์ จำกัด ทำงานภายใต้ระบบบริหารคุณภาพ ISO 9001:2015</span></div></div>
<div class="qv-art-next"><div class="qv-art-svc"><p>บริการที่เกี่ยวข้อง</p><a class="qv-art-svc-l" href="https://qv-test.com/cleanroom-testing/">ทดสอบและรับรองห้องคลีนรูมตาม ISO 14644</a><a class="qv-art-svc-l" href="https://qv-test.com/gmp-pics-audit-readiness/">เตรียมพร้อมรับการตรวจ GMP / PIC/S</a><a class="qv-art-btn" href="/contact/">ขอใบเสนอราคา →</a></div><div class="qv-art-rel"><p>อ่านต่อ</p><ul><li><a href="https://qv-test.com/cleanroom-airflow-types-occupancy-states/">รูปแบบการไหลของอากาศและสถานะการใช้งานของห้องสะอาด (As-built, At-rest, Operational)</a></li><li><a href="https://qv-test.com/dq-iq-oq-pq-difference/">DQ IQ OQ PQ คืออะไร ต่างกันอย่างไร?</a></li></ul></div></div>
<div class="qv-art-cta"><h3>ต้องการตรวจว่าห้องสะอาดพร้อมสำหรับ Annex 1 ฉบับใหม่หรือไม่?</h3><p>ส่งรายการห้อง Grade และรายงานเดิม วิศวกรของเราจะช่วยดูว่ายังขาดการทดสอบส่วนไหน</p><a class="qv-art-btn" href="/contact/">ถามวิศวกร</a></div></div>

]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ห้องสะอาด (Cleanroom) คืออะไร และ Class 100 หรือ Class 10,000 เทียบกับ ISO Class อย่างไร</title>
		<link>https://qv-test.com/what-is-a-cleanroom/</link>
		
		<dc:creator><![CDATA[qvadmin adminadmin]]></dc:creator>
		<pubDate>Sun, 02 Mar 2025 17:27:25 +0000</pubDate>
				<category><![CDATA[มาตรฐานและกฎระเบียบ]]></category>
		<guid isPermaLink="false">http://localhost/qv-test1-3/?p=220</guid>

					<description><![CDATA[นิยามห้องสะอาดตาม ISO 14644-1:2015 และตารางเทียบระดับ FS 209E (Class 100, 10,000, 100,000) กับ ISO Class]]></description>
										<content:encoded><![CDATA[
<div class="qv-art">
<p class="qv-art-cat">มาตรฐานและกฎระเบียบ</p>
<h1 class="qv-art-h1">ห้องสะอาด (Cleanroom) คืออะไร และ Class 100 หรือ Class 10,000 เทียบกับ ISO Class อย่างไร</h1>
<p class="qv-art-meta">เขียนโดย <strong>ทีมวิศวกร QV TEST</strong> · เผยแพร่ 2 มี.ค. 2568 · อัปเดต 26 ต.ค. 2569 · อ่าน 3 นาที</p>
<div class="qv-art-short"><strong>คำตอบสั้น:</strong> ห้องสะอาดคือห้องที่ควบคุมและจำแนกความเข้มข้นของอนุภาคในอากาศ และออกแบบ ก่อสร้าง และใช้งานเพื่อลดการนำเข้า การเกิด และการสะสมของอนุภาค (ISO 14644-1:2015 ข้อ 3.1.1) ระดับแบบเก่าอย่าง Class 100, 10,000 และ 100,000 มาจาก FS 209E ซึ่งถูกยกเลิกในปี 2001 และเทียบได้กับ ISO Class 5, 7 และ 8 ตามลำดับ เมื่อพิจารณาอนุภาค 0.5 µm</div>
<figure class="qv-art-cover"><img fetchpriority="high" width="1024" height="683" src="https://qv-test.com/wp-content/uploads/2025/10/Title-9-1024x683.jpg" class="skip-lazy no-lazy" alt="Cleanroom" data-no-lazy="1" loading="eager" fetchpriority="high" sizes="(min-width:820px) 760px, 100vw" decoding="async" srcset="https://qv-test.com/wp-content/uploads/2025/10/Title-9-1024x683.jpg 1024w, https://qv-test.com/wp-content/uploads/2025/10/Title-9-300x200.jpg 300w, https://qv-test.com/wp-content/uploads/2025/10/Title-9-768x512.jpg 768w, https://qv-test.com/wp-content/uploads/2025/10/Title-9.jpg 1200w" /></figure>
<nav class="qv-art-toc"><p>ในบทความนี้</p><ol><li><a href="#define">นิยามตาม ISO 14644-1:2015</a></li><li><a href="#fs209">FS 209E กับ ISO 14644-1</a></li><li><a href="#where">ใช้ห้องสะอาดในงานใดบ้าง</a></li><li><a href="#faq">คำถามที่พบบ่อย</a></li></ol></nav>
<h2 id="define">นิยามตาม ISO 14644-1:2015</h2>
<p>ISO 14644-1:2015 ข้อ 3.1.1 นิยามห้องสะอาด (cleanroom) ว่าเป็นห้องที่ควบคุมและจำแนกความเข้มข้นของอนุภาคในอากาศ และออกแบบ ก่อสร้าง และใช้งานในลักษณะที่ควบคุมการนำเข้า การเกิด และการสะสมของอนุภาคภายในห้อง ส่วนพื้นที่สะอาด (clean zone) ตามข้อ 3.1.2 คือพื้นที่ที่กำหนดขอบเขตไว้และควบคุมในลักษณะเดียวกัน ซึ่งอาจอยู่ในห้องสะอาดหรือเป็นอุปกรณ์แยกก็ได้</p>
<p>หมายเหตุของนิยามระบุว่าอาจควบคุมพารามิเตอร์อื่นตามความจำเป็นด้วย เช่น อุณหภูมิ ความชื้น ความดัน การสั่นสะเทือน และไฟฟ้าสถิต</p>
<h2 id="fs209">FS 209E กับ ISO 14644-1</h2>
<p>FS 209 ใช้ระบบหน่วยผสม ขนาดอนุภาคเป็นไมโครเมตร แต่ความเข้มข้นเป็นอนุภาคต่อลูกบาศก์ฟุต &#8220;Class 100&#8221; จึงหมายถึงอนุภาคขนาด 0.5 µm ขึ้นไปไม่เกิน 100 อนุภาคต่อลูกบาศก์ฟุต FS 209E (1992) เริ่มใช้หน่วยลูกบาศก์เมตร และ IEST ประกาศยกเลิก FS 209E ในปี 2001</p>
<p>ASHRAE Design Guide for Cleanrooms ระบุว่า 1 m³ ประมาณ 35 ft³ ทั้งสองมาตรฐานจึงใกล้เคียงกันเมื่อวัดอนุภาค 0.5 µm แม้วิธีทดสอบจะต่างกัน</p>
<table><thead><tr><th>ISO 14644-1</th><th>ขีดจำกัด ≥0.5 µm (อนุภาค/m³)</th><th>FS 209E</th></tr></thead><tbody>
<tr><td>ISO Class 3</td><td>35</td><td>Class 1</td></tr>
<tr><td>ISO Class 4</td><td>352</td><td>Class 10</td></tr>
<tr><td>ISO Class 5</td><td>3,520</td><td>Class 100</td></tr>
<tr><td>ISO Class 6</td><td>35,200</td><td>Class 1,000</td></tr>
<tr><td>ISO Class 7</td><td>352,000</td><td>Class 10,000</td></tr>
<tr><td>ISO Class 8</td><td>3,520,000</td><td>Class 100,000</td></tr></tbody></table>
<p class="qv-art-note">ที่มา: ASHRAE Design Guide for Cleanrooms (2017) Table 1.4 ห้องที่ต้องรับรองอย่างเป็นทางการควรระบุเป็น ISO Class ตาม ISO 14644-1:2015</p>
<h2 id="where">ใช้ห้องสะอาดในงานใดบ้าง</h2>
<p>บทนำของ ISO 14644-1:2015 ระบุว่าการควบคุมการปนเปื้อนเป็นประโยชน์ต่อการปกป้องผลิตภัณฑ์หรือความสมบูรณ์ของกระบวนการ ในอุตสาหกรรมเช่น อวกาศ ไมโครอิเล็กทรอนิกส์ ยา เครื่องมือแพทย์ การดูแลสุขภาพ และอาหาร</p>
<h2 id="faq">คำถามที่พบบ่อย</h2><div class="qv-art-faq"><details><summary>Class 10,000 คือ ISO Class อะไร?</summary><p>เทียบได้กับ ISO Class 7 (ขีดจำกัด 352,000 อนุภาค ≥0.5 µm ต่อ m³) ตาม ASHRAE Design Guide for Cleanrooms Table 1.4</p></details><details><summary>ยังใช้ FS 209E รับรองห้องได้หรือไม่?</summary><p>FS 209E ถูกยกเลิกตั้งแต่ปี 2001 การจำแนกระดับปัจจุบันใช้ ISO 14644-1:2015</p></details><details><summary>อากาศในห้องทั่วไปอยู่ระดับใด?</summary><p>ASHRAE Design Guide for Cleanrooms ระบุว่าอากาศในห้องทั่วไปอยู่ราว ISO Class 9 หรือ Class 1,000,000</p></details></div>
<h2 id="refs">เอกสารอ้างอิง</h2><ul class="qv-art-refs"><li>ISO 14644-1:2015 Cleanrooms and associated controlled environments — Part 1: Classification of air cleanliness by particle concentration ข้อ 3.1.1, 3.1.2 และบทนำ</li><li>ASHRAE Design Guide for Cleanrooms: Fundamentals, Systems, and Performance (2017), บทที่ 1 Table 1.3 และ Table 1.4</li></ul>
<div class="qv-art-author"><div class="qv-art-av">QV</div><div><strong>ทีมวิศวกร QV TEST</strong><span>ทีมทดสอบและตรวจรับรองห้องสะอาด ระบบ HVAC และระบบสนับสนุนการผลิต ของบริษัท คิววี เทสต์ จำกัด ทำงานภายใต้ระบบบริหารคุณภาพ ISO 9001:2015</span></div></div>
<div class="qv-art-next"><div class="qv-art-svc"><p>บริการที่เกี่ยวข้อง</p><a class="qv-art-svc-l" href="https://qv-test.com/cleanroom-testing/">ทดสอบและรับรองห้องคลีนรูมตาม ISO 14644</a><a class="qv-art-btn" href="/contact/">ขอใบเสนอราคา →</a></div><div class="qv-art-rel"><p>อ่านต่อ</p><ul><li><a href="https://qv-test.com/iso-14644-1-2015-classification/">ISO 14644-1:2015 เปลี่ยนอะไรจากฉบับ 1999 และจำแนกระดับห้องสะอาดอย่างไร</a></li><li><a href="https://qv-test.com/cleanroom-airflow-types-occupancy-states/">รูปแบบการไหลของอากาศและสถานะการใช้งานของห้องสะอาด (As-built, At-rest, Operational)</a></li></ul></div></div>
<div class="qv-art-cta"><h3>มีคำถามที่ไม่มีในบทความ?</h3><p>ส่งรายละเอียดห้องหรือระบบของคุณ วิศวกรของเราจะตอบกลับพร้อมขอบเขตงาน</p><a class="qv-art-btn" href="/contact/">ถามวิศวกร</a></div></div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>รูปแบบการไหลของอากาศและสถานะการใช้งานของห้องสะอาด (As-built, At-rest, Operational)</title>
		<link>https://qv-test.com/cleanroom-airflow-types-occupancy-states/</link>
		
		<dc:creator><![CDATA[qvadmin adminadmin]]></dc:creator>
		<pubDate>Sun, 02 Mar 2025 17:27:25 +0000</pubDate>
				<category><![CDATA[มาตรฐานและกฎระเบียบ]]></category>
		<guid isPermaLink="false">http://localhost/qv-test1-3/?p=370</guid>

					<description><![CDATA[นิยามลมทิศทางเดียวและไม่ใช่ทิศทางเดียว และสถานะ as-built, at-rest, operational ตาม ISO 14644-1:2015 พร้อมความสัมพันธ์กับ Grade A–D ของ PIC/S]]></description>
										<content:encoded><![CDATA[
<div class="qv-art">
<p class="qv-art-cat">มาตรฐานและกฎระเบียบ</p>
<h1 class="qv-art-h1">รูปแบบการไหลของอากาศและสถานะการใช้งานของห้องสะอาด (As-built, At-rest, Operational)</h1>
<p class="qv-art-meta">เขียนโดย <strong>ทีมวิศวกร QV TEST</strong> · เผยแพร่ 2 มี.ค. 2568 · อัปเดต 26 ต.ค. 2569 · อ่าน 3 นาที</p>
<div class="qv-art-short"><strong>คำตอบสั้น:</strong> ISO 14644-1:2015 แบ่งรูปแบบลมเป็น unidirectional (ลมทิศทางเดียว ขนานกันตลอดหน้าตัด) และ non-unidirectional (ลมผสมกับอากาศในห้อง) และกำหนดสถานะการใช้งาน 3 แบบ คือ as-built, at-rest และ operational ต้องระบุสถานะทุกครั้งที่จำแนกระดับห้อง เพราะขีดจำกัดของ GMP ต่างกันระหว่าง at rest กับ in operation</div>
<figure class="qv-art-cover"><img fetchpriority="high" width="1024" height="768" src="https://qv-test.com/wp-content/uploads/2026/10/ทิศทางลมด้วยควัน-Smoke-Pattern-1024x768.jpg" class="skip-lazy no-lazy" alt="ทดสอบทิศทางลมด้วยควัน (Smoke Pattern)" data-no-lazy="1" loading="eager" fetchpriority="high" sizes="(min-width:820px) 760px, 100vw" decoding="async" srcset="https://qv-test.com/wp-content/uploads/2026/10/ทิศทางลมด้วยควัน-Smoke-Pattern-1024x768.jpg 1024w, https://qv-test.com/wp-content/uploads/2026/10/ทิศทางลมด้วยควัน-Smoke-Pattern-300x225.jpg 300w, https://qv-test.com/wp-content/uploads/2026/10/ทิศทางลมด้วยควัน-Smoke-Pattern-768x576.jpg 768w, https://qv-test.com/wp-content/uploads/2026/10/ทิศทางลมด้วยควัน-Smoke-Pattern-1536x1152.jpg 1536w, https://qv-test.com/wp-content/uploads/2026/10/ทิศทางลมด้วยควัน-Smoke-Pattern-2048x1536.jpg 2048w" /></figure>
<nav class="qv-art-toc"><p>ในบทความนี้</p><ol><li><a href="#airflow">ลมทิศทางเดียว กับ ลมไม่ใช่ทิศทางเดียว</a></li><li><a href="#states">สถานะการใช้งาน 3 แบบ</a></li><li><a href="#grades">สถานะกับ Grade A–D ของ GMP</a></li><li><a href="#faq">คำถามที่พบบ่อย</a></li></ol></nav>
<h2 id="airflow">ลมทิศทางเดียว กับ ลมไม่ใช่ทิศทางเดียว</h2>
<table><thead><tr><th>รูปแบบ</th><th>นิยาม (ISO 14644-1:2015)</th></tr></thead><tbody>
<tr><td>Unidirectional airflow</td><td>อากาศที่ควบคุมให้ไหลผ่านหน้าตัดทั้งหมดของห้องหรือพื้นที่สะอาด ด้วยความเร็วคงที่ และกระแสลมถือว่าขนานกัน (ข้อ 3.2.7)</td></tr>
<tr><td>Non-unidirectional airflow</td><td>อากาศที่จ่ายเข้าห้องผสมกับอากาศภายในด้วยการเหนี่ยวนำ (induction) (ข้อ 3.2.8)</td></tr></tbody></table>
<p>คำว่า &#8220;laminar flow&#8221; ที่ใช้กันทั่วไปไม่ตรงทางเทคนิค ASHRAE Design Guide for Cleanrooms ระบุว่า FS 209D (1988) เปลี่ยนมาใช้คำว่า unidirectional และ nonunidirectional แทน NEBB Table 9-1 ยังแยกห้องแบบลมผสม (mixed airflow) ไว้อีกประเภทหนึ่ง เพื่อเลือกรายการทดสอบให้เหมาะสม</p>
<h2 id="states">สถานะการใช้งาน 3 แบบ</h2>
<table><thead><tr><th>สถานะ</th><th>สภาพห้อง (ISO 14644-1:2015 ข้อ 3.3)</th></tr></thead><tbody>
<tr><td>As-built</td><td>ห้องสร้างเสร็จ ระบบบริการเชื่อมต่อและทำงานแล้ว แต่ยังไม่มีอุปกรณ์ เฟอร์นิเจอร์ วัสดุ และบุคลากร</td></tr>
<tr><td>At-rest</td><td>ติดตั้งอุปกรณ์และเดินเครื่องตามที่ตกลงกันแล้ว แต่ไม่มีบุคลากร</td></tr>
<tr><td>Operational</td><td>ห้องทำงานตามที่กำหนด มีอุปกรณ์เดินเครื่อง และมีบุคลากรตามจำนวนที่กำหนด</td></tr></tbody></table>
<p>NEBB ข้อ 9.3.4 ระบุว่าหน้างานจริงมักไม่ตรงนิยามทั้งหมด เช่น ติดตั้งเครื่องจักรไม่ครบ ผู้ทดสอบต้องบันทึกข้อยกเว้นเหล่านี้ไว้ในรายงาน</p>
<h2 id="grades">สถานะกับ Grade A–D ของ GMP</h2>
<p>PIC/S PE 009-16 Annex 1 ข้อ 4 กำหนดขีดจำกัดอนุภาคแยกตามสถานะ at rest และ in operation ดังนี้ (อนุภาคต่อ m³ ที่มีขนาดเท่ากับหรือใหญ่กว่าขนาดที่ระบุ)</p>
<table><thead><tr><th>Grade</th><th>At rest ≥0.5 µm</th><th>At rest ≥5.0 µm</th><th>In operation ≥0.5 µm</th><th>In operation ≥5.0 µm</th></tr></thead><tbody>
<tr><td>A</td><td>3,520</td><td>20</td><td>3,520</td><td>20</td></tr>
<tr><td>B</td><td>3,520</td><td>29</td><td>352,000</td><td>2,900</td></tr>
<tr><td>C</td><td>352,000</td><td>2,900</td><td>3,520,000</td><td>29,000</td></tr>
<tr><td>D</td><td>3,520,000</td><td>29,000</td><td>ไม่กำหนด</td><td>ไม่กำหนด</td></tr></tbody></table>
<p>ข้อ 5 เทียบเป็น ISO Class ไว้ว่า Grade A เท่ากับ ISO 4.8 (กำหนดโดยขีดจำกัดอนุภาค ≥5.0 µm) Grade B at rest เท่ากับ ISO 5 Grade C เท่ากับ ISO 7 (at rest) และ ISO 8 (in operation) และ Grade D at rest เท่ากับ ISO 8</p>
<p class="qv-art-note">ตารางนี้มาจาก PIC/S PE 009-16 ซึ่งประกาศ สธ. เรื่อง กำหนดหลักเกณฑ์และวิธีการในการผลิตยา พ.ศ. 2569 ให้ใช้สำหรับ Annex 1 ได้ถึง 31 ธ.ค. 2572 หลังจากนั้นใช้ Annex 1 ใน PE 009-17 ซึ่งค่า ≥ 0.5 µm เท่าเดิม แต่ค่า ≥ 5 µm เปลี่ยน เช่น Grade A ไม่กำหนดค่า 5 µm สำหรับการจัดระดับ <a href="https://qv-test.com/moph-gmp-2569-pics-pe-009-17-annex-1/">ดูตารางเปรียบเทียบสองฉบับ</a></p>
<h2 id="faq">คำถามที่พบบ่อย</h2><div class="qv-art-faq"><details><summary>ควรจำแนกระดับห้องในสถานะใด?</summary><p>ขึ้นกับข้อกำหนดที่ใช้ ISO 14644-1 ให้ระบุสถานะทุกครั้ง ส่วน PIC/S Annex 1 กำหนดขีดจำกัดทั้ง at rest และ in operation ยกเว้น Grade D ที่กำหนดเฉพาะ at rest</p></details><details><summary>Grade A เท่ากับ ISO 5 หรือไม่?</summary><p>PIC/S PE 009-16 Annex 1 ข้อ 5 ระบุว่า Grade A เท่ากับ ISO 4.8 เพราะขีดจำกัดอนุภาค ≥5.0 µm ที่ 20 อนุภาคต่อ m³ ส่วน PE 009-17 Annex 1 Table 1 ไม่กำหนดค่า 5 µm ของ Grade A สำหรับการจัดระดับ จึงจัดตามค่า ≥0.5 µm ที่ 3,520 (ISO 5)</p></details></div>
<h2 id="refs">เอกสารอ้างอิง</h2><ul class="qv-art-refs"><li>ISO 14644-1:2015 Cleanrooms and associated controlled environments — Part 1: Classification of air cleanliness by particle concentration ข้อ 3.2.7, 3.2.8 และ 3.3</li><li>PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-16 (1 กุมภาพันธ์ 2022), Annex 1: Manufacture of sterile medicinal products ข้อ 4–5</li><li>PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-17 (25 สิงหาคม 2023), Annex 1 ข้อ 4.27 Table 1</li><li>ประกาศกระทรวงสาธารณสุข เรื่อง กำหนดหลักเกณฑ์และวิธีการในการผลิตยา ตามกฎหมายว่าด้วยยา พ.ศ. 2569 ข้อ 3</li><li>NEBB Procedural Standards for Certified Testing of Cleanrooms (CPT), Section 9: Cleanroom Tests ข้อ 9.3–9.7, Table 9-1 และ Table 9-2</li><li>ASHRAE Design Guide for Cleanrooms: Fundamentals, Systems, and Performance (2017), บทที่ 1 ข้อ 1.5</li></ul>
<div class="qv-art-author"><div class="qv-art-av">QV</div><div><strong>ทีมวิศวกร QV TEST</strong><span>ทีมทดสอบและตรวจรับรองห้องสะอาด ระบบ HVAC และระบบสนับสนุนการผลิต ของบริษัท คิววี เทสต์ จำกัด ทำงานภายใต้ระบบบริหารคุณภาพ ISO 9001:2015</span></div></div>
<div class="qv-art-next"><div class="qv-art-svc"><p>บริการที่เกี่ยวข้อง</p><a class="qv-art-svc-l" href="https://qv-test.com/cleanroom-testing/">ทดสอบและรับรองห้องคลีนรูมตาม ISO 14644</a><a class="qv-art-btn" href="/contact/">ขอใบเสนอราคา →</a></div><div class="qv-art-rel"><p>อ่านต่อ</p><ul><li><a href="https://qv-test.com/iso-14644-1-2015-classification/">ISO 14644-1:2015 เปลี่ยนอะไรจากฉบับ 1999 และจำแนกระดับห้องสะอาดอย่างไร</a></li><li><a href="https://qv-test.com/what-is-a-cleanroom/">ห้องสะอาด (Cleanroom) คืออะไร และ Class 100 หรือ Class 10,000 เทียบกับ ISO Class อย่างไร</a></li></ul></div></div>