<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Standards &amp; Regulations &#8211; Clean Room Validation &amp; Certification Standard NEBB ISO</title>
	<atom:link href="https://qv-test.com/en/category/standards-regulations-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://qv-test.com</link>
	<description>Clean Room Validation &#38; Certification Standard NEBB ISO</description>
	<lastBuildDate>Tue, 27 Oct 2026 02:38:10 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://qv-test.com/wp-content/uploads/2025/09/Asset-3-150x150.png</url>
	<title>Standards &amp; Regulations &#8211; Clean Room Validation &amp; Certification Standard NEBB ISO</title>
	<link>https://qv-test.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Thailand&#8217;s 2026 GMP Notification: PIC/S PE 009-17 and When the New Annex 1 Applies</title>
		<link>https://qv-test.com/en/thailand-gmp-notification-2026-pics-pe-009-17-annex-1/</link>
		
		<dc:creator><![CDATA[qvadmin adminadmin]]></dc:creator>
		<pubDate>Tue, 27 Oct 2026 02:38:09 +0000</pubDate>
				<category><![CDATA[Standards & Regulations]]></category>
		<guid isPermaLink="false">https://qv-test.com/thailand-gmp-notification-2026-pics-pe-009-17-annex-1/</guid>

					<description><![CDATA[Thailand's MOPH GMP notification B.E. 2569 adopts PIC/S PE 009-17, with Annex 1 following PE 009-16 until 31 December 2029. What changes for cleanroom particle limits, requalification and testing.]]></description>
										<content:encoded><![CDATA[
<div class="qv-art">
<p class="qv-art-cat">Standards &#038; Regulations</p>
<h1 class="qv-art-h1">Thailand&#8217;s 2026 GMP Notification: PIC/S PE 009-17 and When the New Annex 1 Applies</h1>
<p class="qv-art-meta">By <strong>QV TEST engineering team</strong> · Published 27 Oct 2026 · Updated 27 Oct 2026 · 5 min read</p>
<div class="qv-art-short"><strong>Short answer:</strong> The Ministry of Public Health notification on rules and methods for drug manufacturing B.E. 2569 (2026) requires modern drug manufacturers in Thailand to follow the PIC/S GMP Guide PE 009-17, except Annex 1 (manufacture of sterile medicinal products), which may follow PE 009-16 until 31 December 2029 (B.E. 2572). For cleanrooms, the ≥ 0.5 µm limits for Grades A–D are unchanged, while the ≥ 5 µm limits, requalification intervals and qualification tests are set out more explicitly in the PE 009-17 Annex 1.</div>
<figure class="qv-art-cover"><img fetchpriority="high" width="1024" height="765" src="https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-1024x765.webp" class="skip-lazy no-lazy" alt="ชั้นเอกสารรายงานการทดสอบสำหรับเตรียมรับการตรวจ GMP PIC/S" data-no-lazy="1" loading="eager" fetchpriority="high" sizes="(min-width:820px) 760px, 100vw" decoding="async" srcset="https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-1024x765.webp 1024w, https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-300x224.webp 300w, https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness-768x574.webp 768w, https://qv-test.com/wp-content/uploads/2026/10/qv-hero-gmp-pics-audit-readiness.webp 1400w" /></figure>
<nav class="qv-art-toc"><p>In this article</p><ol><li><a href="#notice">What the notification sets out</a></li><li><a href="#timeline">Which Annex 1 applies when</a></li><li><a href="#particles">What changed in the particle limits</a></li><li><a href="#tests">Cleanroom qualification under PE 009-17</a></li><li><a href="#prepare">What to prepare now</a></li><li><a href="#faq">FAQ</a></li></ol></nav>
<h2 id="notice">What the notification sets out</h2>
<table><thead><tr><th>Topic</th><th>Key point</th><th>Clause</th></tr></thead><tbody>
<tr><td>Dates</td><td>Signed 1 July 2026, published in the Royal Gazette on 3 July 2026 (Vol. 143, Special Part 164 Ng). It takes effect after 30 days from publication in the Royal Gazette.</td><td>1</td></tr>
<tr><td>Repealed notifications</td><td>The B.E. 2559 (2016) notification on traditional drug manufacturing and the B.E. 2567 (2024) notification on modern drug manufacturing</td><td>2</td></tr>
<tr><td>Standard adopted</td><td>PIC/S Guide to Good Manufacturing Practice for Medicinal Products Part I, Part II and Annexes, PE 009-17 (Appendix 1 of the notification)</td><td>3</td></tr>
<tr><td>Exceptions</td><td>Annex 1 follows PE 009-16 until 31 December 2029; Annex 6 (manufacture of medicinal gases) is excluded</td><td>3 (1)–(2)</td></tr>
<tr><td>Veterinary autogenous vaccines</td><td>Follow the EU Adapted GMP principles for inactivated veterinary autogenous vaccines (Appendix 2)</td><td>4</td></tr>
</tbody></table>
<h2 id="timeline">Which Annex 1 applies when</h2>
<table><thead><tr><th>Period</th><th>Annex 1 under the notification</th></tr></thead><tbody>
<tr><td>From the effective date to 31 Dec 2029</td><td>Annex 1 of PIC/S PE 009-16</td></tr>
<tr><td>After 31 Dec 2029</td><td>Annex 1 of PIC/S PE 009-17 (dated 25 August 2023, attached to the notification)</td></tr>
</tbody></table>
<p>The rest of the GMP Guide (Part I, Part II and the other Annexes except Annex 6) follows PE 009-17 from the effective date. Sterile manufacturers therefore have a transition period for Annex 1, but cleanrooms, qualification records and monitoring programmes should be ready before the end of 2029.</p>
<h2 id="particles">What changed in the particle limits</h2>
<p>Comparison of maximum particle limits for cleanroom classification (particles per m³)</p>
<table><thead><tr><th>Grade</th><th>≥ 0.5 µm at rest / in operation (both editions)</th><th>≥ 5 µm, PE 009-16</th><th>≥ 5 µm, PE 009-17 (Table 1)</th></tr></thead><tbody>
<tr><td>A</td><td>3,520 / 3,520</td><td>20 / 20</td><td>Not specified (a) / Not specified (a)</td></tr>
<tr><td>B</td><td>3,520 / 352,000</td><td>29 / 2,900</td><td>Not specified (a) / 2,930</td></tr>
<tr><td>C</td><td>352,000 / 3,520,000</td><td>2,900 / 29,000</td><td>2,930 / 29,300</td></tr>
<tr><td>D</td><td>3,520,000 / not defined</td><td>29,000 / not defined</td><td>29,300 / not predetermined (b)</td></tr>
</tbody></table>
<p class="qv-art-note">(a) PE 009-17 states that classification including 5 µm particles may be considered where indicated by the CCS or historical trends. (b) For Grade D in operation, the manufacturer sets limits based on risk assessment and routine data. For monitoring, Table 5 of PE 009-17 sets the ≥ 5 µm limit at 29 for Grade A and for Grade B at rest.</p>
<p>PE 009-16 clause 5 states that Grade A corresponds to ISO 4.8, driven by the ≥ 5.0 µm limit of 20 particles per m³. In PE 009-17, Grade A classification is based on the ≥ 0.5 µm limit of 3,520.</p>
<h2 id="tests">Cleanroom qualification under PE 009-17</h2>
<p>PE 009-17 Annex 1 clause 4.25 lists the tests for qualifying cleanrooms and clean air equipment (where relevant to the design or operation): installed filter leakage and integrity, airflow volume and velocity, air pressure difference, airflow direction and visualisation, airborne and surface microbial contamination, temperature, relative humidity, recovery, and containment leak testing.</p>
<table><thead><tr><th>Topic</th><th>What PE 009-17 Annex 1 requires</th><th>Clause</th></tr></thead><tbody>
<tr><td>States for classification</td><td>Both at rest and in operation; at-rest limits must be met after a clean-up period (guidance value under 20 minutes)</td><td>4.29</td></tr>
<tr><td>Unidirectional air speed</td><td>Guidance value 0.36–0.54 m/s at the working position, unless scientifically justified in the CCS</td><td>4.30</td></tr>
<tr><td>Microbial limits during qualification (Table 2)</td><td>Grade A no growth · B: air 10 CFU/m³, settle plates 5 CFU/4 h, contact plates 5 CFU · C: 100 / 50 / 25 · D: 200 / 100 / 50</td><td>4.31</td></tr>
<tr><td>Minimum requalification</td><td>Particle classification, final filter integrity, airflow volume, pressure difference and air velocity (for Grades B, C and D per the CCS risk assessment; in non-unidirectional areas, recovery testing replaces velocity testing)</td><td>4.32</td></tr>
<tr><td>Maximum requalification interval</td><td>Grade A and B: 6 months · Grade C and D: 12 months, plus after remedial action or significant change</td><td>4.32</td></tr>
<tr><td>Sampling locations</td><td>Minimum per ISO 14644-1, with additional locations considered in Grade A and B areas such as the point of fill</td><td>4.28</td></tr>
</tbody></table>
<h2 id="prepare">What to prepare now</h2>
<ul>
<li>Check that existing classification reports include ≥ 5 µm and microbial results for both at rest and in operation.</li>
<li>Confirm requalification intervals do not exceed 6 months for Grade A and B and 12 months for Grade C and D.</li>
<li>Define and record the clean-up period for each room during qualification.</li>
<li>Review the justification for unidirectional air speeds and recovery testing in non-unidirectional areas.</li>
<li>Link test results to the contamination control strategy (CCS) under clause 2.3.</li>
</ul>
<h2 id="faq">FAQ</h2><div class="qv-art-faq"><details><summary>Which Annex 1 applies now?</summary><p>Under clause 3 (1) of the B.E. 2569 notification, Annex 1 of PE 009-16 may be used until 31 December 2029; after that, PE 009-17 applies.</p></details><details><summary>Have the ≥ 0.5 µm limits for Grades A–D changed?</summary><p>No. Both PE 009-16 and PE 009-17 use 3,520 / 352,000 / 3,520,000 particles per m³ for the same grades and states. The change is in the ≥ 5 µm limits.</p></details><details><summary>How often must cleanrooms be requalified?</summary><p>PE 009-17 Annex 1 clause 4.32 sets maximum intervals of 6 months for Grade A and B and 12 months for Grade C and D.</p></details></div>
<h2 id="refs">References</h2><ul class="qv-art-refs"><li>Notification of the Ministry of Public Health on rules and methods for drug manufacturing under the drug law, B.E. 2569 (Royal Gazette Vol. 143, Special Part 164 Ng, 3 July 2026), clauses 1–4</li><li>PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-17 (25 August 2023), Annex 1: Manufacture of sterile medicinal products, clauses 2.3, 4.25–4.32, Tables 1, 2 and 5</li><li>PIC/S Guide to Good Manufacturing Practice for Medicinal Products, PE 009-16 (1 February 2022), Annex 1, clauses 4–5</li></ul>
<div class="qv-art-author"><div class="qv-art-av">QV</div><div><strong>QV TEST engineering team</strong><span>The cleanroom, HVAC and utility testing team of QV TEST Co., Ltd., working under an ISO 9001:2015 quality management system.</span></div></div>
<div class="qv-art-next"><div class="qv-art-svc"><p>Related services</p><a class="qv-art-svc-l" href="https://qv-test.com/en/cleanroom-testing-certification/">Cleanroom testing and certification to ISO 14644</a><a class="qv-art-svc-l" href="https://qv-test.com/en/gmp-inspection-readiness/">GMP / PIC/S inspection readiness</a><a class="qv-art-btn" href="/en/request-a-quote/">Request a quote →</a></div><div class="qv-art-rel"><p>Read next</p><ul><li><a href="https://qv-test.com/en/dq-iq-oq-pq-explained/">DQ, IQ, OQ and PQ: What Are They and How Do They Differ?</a></li><li><a href="https://qv-test.com/en/warehouse-temperature-mapping-sensors/">Warehouse Temperature Mapping: How Is It Done and How Many Sensors Do You Need?</a></li></ul></div></div>
<div class="qv-art-cta"><h3>Want to check whether your cleanrooms are ready for the new Annex 1?</h3><p>Send your room list, grades and existing reports, and our engineers will point out which tests are missing.</p><a class="qv-art-btn" href="/en/request-a-quote/">Ask an engineer</a></div></div>

]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>